Description
Product Details
CU-3E19RBU-5
2-3 Zone; 1.5 Ton multi-zone outdoor condenser unit provides heating and cooling for 2-3 indoor units and -21°C (-5°F) cold climate heat operation. Select wall mount, 4-way cassette or slim duct units for indoor installation.
nanoe™ X ClimaPure™ Compatibility
Panasonic heat pumps come with built-in WiFi connectivity, air and surface purification technology that provides a comfortable environment for occupants by reducing pollutants and odours.
Compatible with CS-XE9WKUAW, CS-XE12WKUAW, CS-XE15WKUAW, CS-XE18WKUAW, and CS-XE24WKUAW indoor units.
Key Features
- Cooling Capacity: 19,000 (6,100 – 24,800) Btu/h
- Heating Capacity: 26,000 (5,000 – 28,400) Btu/h
- SEER Non-Ducted 22.0 / Ducted 18.5
- SEER Non-Ducted 12.55 / Ducted 10.85;
- HSPF Non-Ducted 10.5 / Ducted 9.0
- ENERGY STAR Non-Ducted
- nanoe™ X ClimaPure™ Compatibility
Eligible for the The Canada Greener Homes Grant
| Outdoor Unit | Indoor Unit | Grant Amount |
|---|---|---|
| CU-3E19RBU-5 | 3 IDUs | $5000 |
| CU-3E19RBU-5 | 2 IDUs | $2500 |
Product Specifications
| Capacity Cooling (BTU/H) | 19,000 (6,000 – 24,000) |
|---|---|
| Capacity Heating (BTU/H) | 26,000 (5,000 – 28,400) |
| SEER – Cooling | Non-Ducted 22.0 / Ducted 18.5 |
| EER – Cooling | Non-Ducted 12.55 / Ducted 10.85 |
| HSPF – Heating | Non-Ducted 10.5 / Ducted 9.0 |
| Power Supply (V, Phase, Hz) | 208 ~ 230V, 1PH, 60Hz |
| Running Amps – Cooling (A) | Non-Ducted 7.4-6.7 / Ducted 8.5-7.7 |
| Running Amps – Heating (A) | Non-Ducted 10.1-9.1 / Ducted 12.3-11.1 |
| Power Input – Cooling (W) | 1,510 (360-2,420) |
| Power Input – Heating (W) | 2,060 (320-2,300) |
| Controls | Microprocessor |
| Fan Speeds | Variable Speed |
| Compressor | Twin Rotary, DC Motor, Inverter |
| Refrigerant | R-410A / 93.2 oz. |
| Refrigerant Control | Electric Expansion Valve |
| Operation Sound – Outdoor (Hi) (dB-A) Cooling | 50 |
| Operation Sound – Outdoor (Hi) (dB-A) Heating | 52 |
| Refrigerant Tubing Connections | Flare |
| Max. Allowable Tubing Length (ft) | 164 per system (82 per indoor unit) |
| Refrigerant Tube Diameter – Discharge (IN) | 1/4″ × 3 |
| Refrigerant Tube Diameter – Suction (IN) | 3/8″ × 3 |
| Adapter Required | Indoor 12 and 18 Btu/hr. require 1 CZ-MA1P-US |
| Dimensions (H × W × D) | 31 5⁄16″ × 34 15⁄32″ × 14 3⁄16″ |
| Net Weight (LBS) | 159 |