fbpx
X
  • No products in the list

IBC VX Series

IBC VX Series,

Residential – Heating

With the launch of the IBC VX Series high-efficiency modulating condensing boiler, IBC® will be positioned to offer unprecedented value in the residential new and retro fit marketplace. The VX™ offers the same great quality, control features and efficiency you expect from an IBC® stainless steel fire tube boiler but in a more compact design , saving time, space and money.

SKU N/A Category Tag

IBC VX Series  VX 110 | VX 150 | VX 199

IBC VX Series

Residential High Efficiency Condensing Boilers

Compact design saving time, space and money

With the launch of the IBC VX Series high-efficiency modulating condensing boiler, IBC® will be positioned to offer unprecedented value in the residential new and retro fit marketplace. The VX™ offers the same great quality, control features and efficiency you expect from an IBC® stainless steel fire tube boiler but in a more compact design , saving time, space and money.

Touch Screen Boiler Controller:
• Express setup
• Remote monitoring & diagnostics
• Easy USB programmability
• Cascade up to 4 units
• Intuitive alert system
• Simplified load pairing
• Visible flame current data for troubleshooting
· 95% AFUE
· Built-in 4 zone pump or valve control in addition to the primary control. 5 pumps total. Replacing the need for external pump controls
· PVC/CPVC/PPs approved – venting up to 240ft (each side) on the VX 110
· MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler.
· Built-in CSA/UL approved LWCO and manual reset high limit.
· Connect your IBC Indirect Water Tank directly to the boiler without a primary loop.
· Turndown ratio of up to 6.5:1 means you have the power to heat your home in the coldest weather, yet reduce short cycling when the weather is mild.
· Built-in outdoor reset control of water temperature.
· Reverse flow detection.
· 5 Year limited manufacturer’s parts warranty.
· Limited 15 year residential heat exchanger warranty.

IBC VX Series Documentation

List of Manuals (IBC VX Series)


↓ VX Series Installation & Operating Instruction Manual
↓ VX Series User Manual
↓ V-10 Controller Manual
↓ Quick Reference Installation Guide

List of Literature (IBC VX Series)


↓ VX Series Sales Brochure
↓ VX Sales Specification Sheet
↓ VX Illustrated Parts List
↓ Engineering Submittal
↓ Warranty

IBC VX Series Technical Data


Specifications VX 110 VX 150 VX 199
CSA Input (Natural Gas or Propane *) – MBH 16.9 – 110 23 – 150 30.6 – 199
CSA Input (Natural Gas or Propane *) – KW 5 – 32.2 6.7 – 44 8.8 – 58.3
CSA Output – MBH 16.2 – 101.5 22 – 138.5 29.2 – 183.7
CSA Output – KW 4.74 – 29.8 6.5 – 40.6 8.6 – 53.8
A.F.U.E 95% 95% 95%
Min gas pressure (Nat. Gas or Propane) – inch w.c. 4 4 4
Max gas pressure (Nat. Gas or Propane) – inch w.c. 14 14 14
Power (120Vac/60Hz) – Watts @ full fire – Watts ( without pumps) 54 54 73
Weight (empty) – lbs/Kg 67 / 30.4 78 / 35.4 88 / 39.9
Pressure vessel water content – USG/Liters 1.88 / 7.12 2.79 / 10.56 3.51 / 13.29
Max boiler flow rate – USgpm 14 19 25
Min boiler flow rate – USgpm 2 3 4
Max operating pressure – psig 50 50 30
Min water pressure – psig 8 8 8
Approved installation altitude – ASL 0 – 12,000 ft 0 – 12,000 ft 0 – 12,000 ft
Ambient temperature – Low (°F/°C) 32°F / 0°C 32°F / 0°C 32°F / 0°C
Ambient temperature – High (°F/°C) 122°F / 50°C 122°F / 50°C 122°F / 50°C
Max relative humidity (non-condensing) 90% 90% 90%
Min water temperature (°F/°C) 34°F / 1°C 34°F / 1°C 34°F / 1°C
Max water temperature (electronic-limit) (°F/°C) 190°F / 88°C 190°F / 88°C 190°F / 88°C
Max ΔT – supply / return (electronic fence) 40°F / 22.2°C 40°F 40°F
Maximum equivalent vent length, each side 2” 100′ 50′ N/A
Maximum equivalent vent length, each side 3” 240′ 170′ 100′

Exhaust pipe size VX 110 VX 150 VX 199
Sched.40; Rigid PPs (each side) (each side) (each side)
2” 100’ 50’ Not allowed
3” 240’ 170’ 100’
90° long sweep elbow Allow 5’ equivalent Allow 5’ equivalent Allow 5’ equivalent
90° vent elbow Allow 8’ equivalent Allow 8’ equivalent Allow 8’ equivalent
45° elbow Allow 3’ equivalent Allow 3’ equivalent Allow 3’ equivalent
PPs 87-90° elbows Allow 8’ equivalent Allow 8’ equivalent Allow 8’ equivalent
2” SS Sidewall Terminal No additional allowance Not allowed Not allowed
3” SS Sidewall Terminal (exhaust vent) Allow 20’ equiv. of 3” Sched 40 Not allowed Not allowed
Flexible PPs
3” Flexible
45’ (max) 45’ (max) 30’ (max)
Actual lineal x 1.2 = equivalent Actual lineal x 1.2 = equivalent Actual lineal x 3.3 = equivalent

-Fuel Conversion kit included
-Boilers are shipped with a 30 psi relief valve

Need more info? Contact Us

 

Additional information

Models

VX 110, VX 150, VX 199