Description
|
Touch Screen Boiler Controller:
• Express setup • Remote monitoring & diagnostics • Easy USB programmability • Cascade up to 4 units • Intuitive alert system • Simplified load pairing
• Visible flame current data for troubleshooting |
| · 95% AFUE |
|
· Built-in 4 zone pump or valve control in addition to the primary control. 5 pumps total. Replacing the need for external pump controls
|
|
· PVC/CPVC/PPs approved – venting up to 240ft (each side) on the VX 110
|
|
· MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler.
|
| · Built-in CSA/UL approved LWCO and manual reset high limit. |
|
· Connect your IBC Indirect Water Tank directly to the boiler without a primary loop.
|
|
· Turndown ratio of up to 6.5:1 means you have the power to heat your home in the coldest weather, yet reduce short cycling when the weather is mild.
|
| · Built-in outdoor reset control of water temperature. |
| · Reverse flow detection. |
| · 5 Year limited manufacturer’s parts warranty. |
|
· Limited 15 year residential heat exchanger warranty.
|
IBC VX Series Documentation
List of Manuals (IBC VX Series)
| ↓ VX Series Installation & Operating Instruction Manual |
| ↓ VX Series User Manual |
| ↓ V-10 Controller Manual |
| ↓ Quick Reference Installation Guide |
List of Literature (IBC VX Series)
| ↓ VX Series Sales Brochure |
| ↓ VX Sales Specification Sheet |
| ↓ VX Illustrated Parts List |
| ↓ Engineering Submittal |
| ↓ Warranty |
IBC VX Series Technical Data
| Specifications | VX 110 | VX 150 | VX 199 | |
| CSA Input (Natural Gas or Propane *) – MBH | 16.9 – 110 | 23 – 150 | 30.6 – 199 | |
| CSA Input (Natural Gas or Propane *) – KW | 5 – 32.2 | 6.7 – 44 | 8.8 – 58.3 | |
| CSA Output – MBH | 16.2 – 101.5 | 22 – 138.5 | 29.2 – 183.7 | |
| CSA Output – KW | 4.74 – 29.8 | 6.5 – 40.6 | 8.6 – 53.8 | |
| A.F.U.E | 95% | 95% | 95% | |
| Min gas pressure (Nat. Gas or Propane) – inch w.c. | 4 | 4 | 4 | |
| Max gas pressure (Nat. Gas or Propane) – inch w.c. | 14 | 14 | 14 | |
| Power (120Vac/60Hz) – Watts @ full fire – Watts ( without pumps) | 54 | 54 | 73 | |
| Weight (empty) – lbs/Kg | 67 / 30.4 | 78 / 35.4 | 88 / 39.9 | |
| Pressure vessel water content – USG/Liters | 1.88 / 7.12 | 2.79 / 10.56 | 3.51 / 13.29 | |
| Max boiler flow rate – USgpm | 14 | 19 | 25 | |
| Min boiler flow rate – USgpm | 2 | 3 | 4 | |
| Max operating pressure – psig | 50 | 50 | 30 | |
| Min water pressure – psig | 8 | 8 | 8 | |
| Approved installation altitude – ASL | 0 – 12,000 ft | 0 – 12,000 ft | 0 – 12,000 ft | |
| Ambient temperature – Low (°F/°C) | 32°F / 0°C | 32°F / 0°C | 32°F / 0°C | |
| Ambient temperature – High (°F/°C) | 122°F / 50°C | 122°F / 50°C | 122°F / 50°C | |
| Max relative humidity (non-condensing) | 90% | 90% | 90% | |
| Min water temperature (°F/°C) | 34°F / 1°C | 34°F / 1°C | 34°F / 1°C | |
| Max water temperature (electronic-limit) (°F/°C) | 190°F / 88°C | 190°F / 88°C | 190°F / 88°C | |
| Max ΔT – supply / return (electronic fence) | 40°F / 22.2°C | 40°F | 40°F | |
| Maximum equivalent vent length, each side 2” | 100′ | 50′ | N/A | |
| Maximum equivalent vent length, each side 3” | 240′ | 170′ | 100′ |
| Exhaust pipe size | VX 110 | VX 150 | VX 199 |
| Sched.40; Rigid PPs | (each side) | (each side) | (each side) |
| 2” | 100’ | 50’ | Not allowed |
| 3” | 240’ | 170’ | 100’ |
| 90° long sweep elbow | Allow 5’ equivalent | Allow 5’ equivalent | Allow 5’ equivalent |
| 90° vent elbow | Allow 8’ equivalent | Allow 8’ equivalent | Allow 8’ equivalent |
| 45° elbow | Allow 3’ equivalent | Allow 3’ equivalent | Allow 3’ equivalent |
| PPs 87-90° elbows | Allow 8’ equivalent | Allow 8’ equivalent | Allow 8’ equivalent |
| 2” SS Sidewall Terminal | No additional allowance | Not allowed | Not allowed |
| 3” SS Sidewall Terminal (exhaust vent) | Allow 20’ equiv. of 3” Sched 40 | Not allowed | Not allowed |
| Flexible PPs | |||
|
3” Flexible
|
45’ (max) | 45’ (max) | 30’ (max) |
| Actual lineal x 1.2 = equivalent | Actual lineal x 1.2 = equivalent | Actual lineal x 3.3 = equivalent |
-Fuel Conversion kit included
-Boilers are shipped with a 30 psi relief valve
Need more info? Contact Us